What Helicobacter Test INFAI for children of the age 3-11contains
- The active substance is 13C-urea.
One jar contains 45 mg 13C-urea.
- There are no other ingredients.
What Helicobacter Test INFAI for children of the age 3-11 looks like and contents of the pack Helicobacter Test INFAI for children of the age 3-11 years is a clear, colourless powder for oral solution.
Content of the Test Kit:
No. Component Quantity 1 Jar 10 ml volume, polystyrene with polyethylene snap cap containing 45 mg 13C-urea powder for oral solution 1 2 Labelled sample glass- or plastic containers for sampling, storing and transporting the breath samples for analysis Sampling time 00-minute-value Sampling time 30-minute-value 2 2 3 Bendable straw for collection of the breath samples into the corresponding sample tubes 1 4 Data sheet for patient documentation 1 5 Package leaflet 1 6 Page of barcode labels and sticker 1
Marketing Authorisation Holder and Manufacturer
INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH
Universitätsstraße 142
D-44799 Bochum
Germany
For any information about this medicinal product, please contact the local representative of the Marketing Authorisation Holder.
BelgiëBelgiqueBelgien INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum TélTel 49 234 971130 LuxembourgLuxemburg INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum TélTel 49 234 971130 INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Te. 49 234 971130 Magyarország INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel. 49 234 971130 eská republika INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Malta INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Denmark BioCare Nordic ApS Langebjergvaenget 8A DK-4000 Roskilde Tlf 45 4646 1191 Nederland INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Deutschland INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Norge INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tlf 49 234 971130 Eesti INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Österreich INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Faran Laboratories s.a. GR-14564 30 210 626 9200 Polska INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel. 49 234 971130 Portugal Goldfarma Lda Rua Professor Francisco Gentil No 22-F P-2620-097 Povoa de Santo Adrião Tel 351 219383280 España INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130
France Bioprojet Pharma 9, rue Rameau F-75002 Paris Tél 33 1 470 366 33 România INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Slovenija PLIVA Ljubljana d.o.o. Pot k sejmiu 35 SI-1231 Ljubljana-rnue Tel 386 1 58 90 390 Ireland INFAI UK Ltd. York Science Park Innovation Centre University Road, Heslington GB-York YO10 5DG Tel 44 1904 435 228 Slovenská republika ALLMEDICAL s.r.o. Popradská 7 SK-040 01 Koice Tel 421 57 44 50030 Ísland INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Sími 49 234 971130 Italia INFAI Italia S.r.l. via Borgogna 2 I-20112 Milano Tel. 39 0481 790350 SuomiFinland INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum PuhTel 49 234 971130 INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum 49 234 971130 Sverige INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 Latvija INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130 United Kingdom INFAI UK Ltd. York Science Park Innovation Centre University Road, Heslington GB-York YO10 5DG Tel. 44 1904 435 228 Lietuva INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstraße 142 D-44799 Bochum Tel 49 234 971130
This leaflet was last approved in MM/YYYY
-------------------------------------------------------------------------------------------------------------------------------- The following information is intended for medical or healthcare professionals only:
Analysis of breath samples and testing specification for laboratories
The breath samples, collected in 10 ml glass- or plastic sample tubes, are analysed by isotope ratio mass spectrometry (IRMS).
The analysis of the 13C/ 12C-ratio in carbon dioxide of breath is an integrated part of the diagnostic test Helicobacter Test INFAI. The accuracy of the test strongly depends on the quality of the breath analysis. The specification of breath analysis parameters like linearity, stability (reference gas precision), and precision of measurement are fundamental for the accuracy of the system.
It has to be ensured that the analysis is carried out by a qualified laboratory. The method validated in the application is as follows:
- Sample preparation for (IRMS)
To determine the 13C/ 12C-ratio of carbon dioxide in breath by mass spectrometric analysis the carbon dioxide must be separated from the breath and introduced into the mass spectrometer. The automatic preparation system for isotope mass spectrometers which is dedicated for breath test analysis is based on a gas-chromatographic continuous flow separation technique.
Water is removed from the sample by means of a Nafion water trap or the gas-chromatographic preparation system that separates the individual gases in a gas chromatographic column with Helium as eluent. Passing the column the separated gas species of breath are detected by an ionisation detector. The fraction of carbon dioxide gas, identified by its characteristic retention time, is introduced into mass spectrometer.
- Mass spectrometric analysis
To analyse the separated carbon dioxide sample gas its molecules must be ionised, formed into a beam, accelerated by an electric field, deflected in a magnetic field, and finally detected. These five processes take place in the analyser of a mass spectrometer, which consists of three separate sections: the source, flight tube, and collector. Ionisation, beam formation and acceleration all occur in the source, magnetic deflection takes place in the flight tube and detection takes place in the collector.
For introduction of the carbon dioxide into the analyser many sample inlet systems are available. For breath test analysis the individual balancing of the carbon dioxide of the sample to a reference standard gas is essential. This ensures the high accuracy of this system, as calculation of the isotopic content in carbon dioxide is done with respect to an independent standard.
Specifications for determining 13C12C-ratios
The breath test concept relies on the administration of a specifically 13C-labelled urea whose metabolite utilisation is monitored by measuring 13CO 2 in the expired breath gas.
The mass spectrometer must be capable of:
Multiple replicate analyses Minimum of 3 replicate analyses on the same sample during operation
Security access Storing of operating parameters and of results under security access to avoid later manipulation
Adjustment 13C12C-ratio with respect to Pee Dee Beliminate PDB
Sample loop 200 l
The principle tests to verify the specifications are linearity, stability (reference gas precision), and precision of measurement.
All mass spectrometers for breath analysis must comply with the following specifications:
Linearity - 0.5 for breath samples varying between 1 and 7 CO2concentration
Stability 0.2 on 10 consecutive pulses
Precision of measurement 0.3 for 13C at natural abundance using a 10ml breath sample tube with 3 CO2 breath concentration
C12C of baseline-value and 30-minute-Helicobacter pylori infection is present if the difference in 13value exceeds 4.0 .
Alternatively, any other suitable-validated method may be used, carried out by any objectively qualified laboratory.
MINIMUM PARTICULARS TO APPEAR ON
DATA SHEET FOR PATIENT DOCUMENTATION
1. NAME OF THE MEDICINAL PRODUCT
Helicobacter Test INFAI
2. NAME OF THE MARKETING AUTHORISATION HOLDER
INFAI, Institut für biomedizinische Analytik und NMR-Imaging GmbH Universitätsstr. 142
D-44799 Bochum
Germany
3. EXPIRY DATE
4. BATCH NUMBER
5. OTHER
Date of test
Patient´s full name
Date of birth
Barcode
Doctor/Hospital Address